![]() The results of adding the concentration values as a new keyword is shown in figure 4.įigure 4: Concentration added using the keyword. Keywords can also be added of the Workspace ribbon, which also allows you to create a series of keyword values, making labeling of the keyword easier. After selecting ‘OK, the keyword is added and will appear in the sample workspace where you can fill in the appropriate keyword. In this example, we are adding the keyword concentration to this file containing titration data. You can still readily add keywords in FJX using the Keyword option, which can be found on the FlowJo ribbon, as shown in figure 3įigure 3: Adding keywords during analysis. If you didn’t add keywords at the beginning of your experiment, don’t despair. Finally, the bottom right has a chart of the median of each parameter over time, which is useful for identifying if there were major issues in the acquisition, but more on that later. In the upper right is a list of the parameters, including the voltage that each parameter was run at. This can be very useful for sorting and analyzing the data later on. This way you are assured the correct keywords are carried forward. In fact it is highly encouraged to be adding keywords when setting up the file acquisition on the instrument. Any custom defined keywords will also appear here. To the left is a list of all the keywords that are in the file, from the instrument the data was acquired on to who acquired it and more. The output from this action is shown in figure 2. This information is only a right-click away in FJX.įigure 1: Accessing FCS header information in FJX The header information of the FCS file contains a great deal of information that is very useful to review and extract when performing quality control or troubleshooting. This article will focus on the power of FlowJoX (FJX) and provide some tips and tricks to improve the researchers’ analysis. These keywords are only the tip of the iceberg when it comes to performing advanced analytics. These include define keywords that are added to the file automatically, as well as terms that can be defined by the user. The header file contains what are termed ‘keywords’. The FCS standard divides the file into two components, the listmode file that contains the sequential data from all the detectors. Since the creation of the FCS standard, flow cytometrists have had the ability to analyze data in third party software because of the community’s agreement on the standard. Please navigate through the pages below to dive into more specific details of the Table Editor.Primary data analysis, that is the analysis at the sample or tube level, is where the populations of interest are identified and the necessary data is extracted for secondary analysis. When the table is created, it will batch automatically for all samples in that group.Įach column in FlowJo’s tables can be independently adjusted to include special formatting options ( heat mapping), setting a control value ( won’t iterate), or hidden (calculate but don’t show – useful for equations of equations when you don’t want to show the primary equation). *Please note: when you batch your statistics to the group in the workspace, you only need to drag prototypic statistics from the FIRST sample into the Table Editor. They can be generated for viewing within FlowJo, or exported to many formats and manipulated outside of FlowJo.įlowJo’s tables can be batched, similarly to layouts, including the use of iteration. Tables can be used to show summary statistics, sample keywords, or custom formulas. The Table Editor is FlowJo’s platform for exporting your analyses’ numerical attributes. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |